We determine the parameters that matter
The testing of filter media is important for the development and optimisation of filter materials, as well as for quality assurance during filter production. Increasing quality requirements for filtration solutions make it necessary to better understand the characteristics of the filter media used. In addition to the long-established filtration applications, this has recently also affected personal protective equipment and room air cleaners. At the same time, interest in this area is also being intensified by new mobility concepts such as e-mobility and fuel cell technology. We are also increasing our activities in this field and will be happy to support you with our expertise in the field of material analysis.
As a filter media manufacturer, you design your media as required by your customers’ specific applications. The filter media are tailored to the specific application in terms of their pressure drop behaviour and separation efficiency. In pore size analyses and efficiency measurements, we provide you with the specifications and characteristics that are important to you. In addition, our technologies can be used in the testing of cleanable filter media and mask media.
AFC 131
AFC 131 Test System for characterisation of cleanable filter media acc. VDI 3926-2

AFC 132
AFC132 Test System for characterisation of filter media and small filter elements

AFC 133
AFC 133 Test System for characterisation of cleanable filter media according to ISO 11057

ATM 210
Atomizer Aerosol Generator ATM 210 for aerosol generation from liquids against counter pressure up to 10 bar, compressed air operated, moderate mass flow rate

ATM 210/H
Atomizer Aerosol Generator ATM 210/H for aerosol generation from liquids against counter pressure up to 10 bar, compressed air operated, high mass flow rate

ATM 211
Atomizer Aerosol Generator ATM 211 for aerosol generation from liquids against counter pressure up to 10 bar, compressed air operated, corrosion-resistant

ATM 220
Atomizer Aerosol Generator ATM 220 for aerosol generation from liquids, compressed air operated, base model with broad operational range

ATM 221
Atomizer Aerosol Generator ATM 221 for aerosol generation from liquids, compressed air operated, base model with submerged nozzle

ATM 222
Atomizer Aerosol Generator ATM 222 for aerosol generation from liquids, compressed air operated, pneumitic-controlled, remote controllable

ATM 240/L
Atomizer Aerosol Generator ATM 240/L for aerosol generation from liquids, compressed air operated, high mass flow rate, ideal for PSL aerosols acc. ISO 29463

ATM 240/S
Atomizer Aerosol Generator ATM 240/S for aerosol generation from liquids, compressed air operated, high mass flow rate, ideal for KCl aerosols acc. ISO 16890

DEHS
Liquid aerosol substance DEHS for operation with aerosol generators of the series ATM

DGU 413
Dust Protection Chamber DGU 413 to avoid dust emission during operation of Solid Aerosol Generators of the series SAG410

DIL 540/C
DIL 540/C Dilution System for controlled static dilution (1:100) of aerosols at static air flow rate (28,3 L/min), digital status communication

DIL 541/C
DIL 541/C Dilution System for controlled static dilution (1:10) of aerosols at static air flow rate (28,3 L/min), digital status communication

DIL 545/C
DIL 545/C Dilution System for controlled static dilution (1:100) of aerosols at static air flow rate (3 L/min), digital status communication

DIL 546/C
DIL 546/C Dilution System for controlled static dilution (1:10) of aerosols at static air flow rate (3 L/min), digital status communication

DIL 550
Dilution System DIL 550 for static dilution (1:100) of aerosols at static air flow rate (28,3 L/min)

DIL 551
Dilution System DIL 551 for static dilution (1:10) of aerosols at static air flow rate (28,3 L/min)

DIL 552
Dilution System DIL 552 for static dilution (customised) of aerosols at static air flow rate (28,3 L/min)

DIL 553
DIL 553 Dilution System for static dilution (1:100 or 1:10) of aerosols at static air flow rate (56,6 or 50 L/min)

DIL 557
DIL 550 Dilution System for static dilution (customised) of aerosols at static air flow rate (customised)

EAN 581
Electrostatic Aerosol Neutralizer EAN 581 for generation of positive and/or negative ions for neutralisation or unipolar charging of aerosols

MBP 116
MBP 116 Test System for multiple parameter testing at filter media, space-saving design by vertical-orientated flow channel

PASWin
PASWin software for configuration, control, data logging and data analyses of particle counters and aerosol spectrometer

PSM 165
PSM 165 Pore Size Meter for analysis of pore size distributions of woven, non-woven fabrics and open-pore samples

SAG 420
Solid Aerosol Generator SAG 420 for aerosol generation from powders, belt dosing, high mass flow rates, best for motor intake filter testing acc. ISO 5011

SYS 520
Sample Switching Unit SYS 520 for sampling aerosol samples from to two sample location

Topor
Test fluid Topor for analysis of pore size distributions with Pore Size Meter PSM 165
