Targeted influencing of properties
It is not always possible to generate aerosols in the first step just as they will be subsequently required in the testing process. For this reason, we make targeted changes to properties such as the concentration or the electrostatic charge and can map the changes in the real process or meet standard requirements. The properties of the aerosols that can be influenced include:
- concentration
- particle size distribution
- charge state
Ask us about dilution systems and aerosol neutralisers or supporting equipment such as sampling systems, aerosol substances and dryers.
RFU 564
Regulated Flow Unit RFU 564 for providing variable adjustable and controlled air flow rates up to 100 L/min for underpressure and overpressure operation mode
DDS 560
Dynamic Dilution System DDS 560 for variable-adjustable dilution of aerosols at variable air flow rates
DDU 570/H
Diffusion Dryer Unit DDU 570/H for drying of water-containing aerosols by silica gel, high model
DDU 570/L
Diffusion Dryer Unit DDU 570/L for drying of water-containing aerosols by silica gel, short model
DIL 540/C
DIL 540/C Dilution System for controlled static dilution (1:100) of aerosols at static air flow rate (28,3 L/min), digital status communication
DIL 541/C
DIL 541/C Dilution System for controlled static dilution (1:10) of aerosols at static air flow rate (28,3 L/min), digital status communication
DIL 545/C
DIL 545/C Dilution System for controlled static dilution (1:100) of aerosols at static air flow rate (3 L/min), digital status communication
DIL 546/C
DIL 546/C Dilution System for controlled static dilution (1:10) of aerosols at static air flow rate (3 L/min), digital status communication
DIL 550
Dilution System DIL 550 for static dilution (1:100) of aerosols at static air flow rate (28,3 L/min)
DIL 551
Dilution System DIL 551 for static dilution (1:10) of aerosols at static air flow rate (28,3 L/min)
DIL 552
Dilution System DIL 552 for static dilution (customised) of aerosols at static air flow rate (28,3 L/min)
DIL 553
DIL 553 Dilution System for static dilution (1:100 or 1:10) of aerosols at static air flow rate (56,6 or 50 L/min)
DIL 554
DIL 554 Dilution System for static dilution (1:100) of aerosols at static air flow rate (28,3 L/min) for mobile operation
DIL 554/H
DIL 554/H Dilution System for static dilution (1:100) of aerosols at static air flow rate (56,6 L/min) for mobile operation
DIL 554/T
DIL 554/T Dilution System for static dilution (1:100) of aerosols at static air flow rate (28,3 L/min) for mobile operation, 1/4'' hose connector
DIL 554/Z
DIL 554/Z Dilution System for static dilution (1:10) of aerosols at static air flow rate (28,3 L/min) for mobile operation
DIL 555
DIL 555 Dilution System for static dilution (1:100) of aerosols at static air flow rate (2,83 L/min)
DIL 556
DIL 556 Dilution System for static dilution (1:10) of aerosols at static air flow rate (2,83 L/min)
DIL 557
DIL 550 Dilution System for static dilution (customised) of aerosols at static air flow rate (customised)
EAN 581
Electrostatic Aerosol Neutralizer EAN 581 for generation of positive and/or negative ions for neutralisation or unipolar charging of aerosols
EMS 755
Electromagnetic Sieve Vibrator EMS 755 for finest grain sieving of dry powders (dry sieving) or suspensions (wet sieving)
GMS 141
GMS 141 gravimetric sampling system of oil concentrations at Blow-By oil mist separators
SYS 520
Sample Switching Unit SYS 520 for sampling aerosol samples from to two sample location
SYS 528
Rectangular Sampling Probe SYS 528 for leakage and integrity testing according ISO 14644-3 for a sample flow rate of 50 l/min
SYS 529
Rectangular Sampling Probe SYS 529 for leakage and integrity testing according ISO 14644-3 for a sample flow rate of 28,3 l/min
TDC 584
Conditioning cabinet TDC 584 to discharge air filter and air filter media by isopropanol vapor according to ISO 16890-4
TDC 585
Conditioning chamber TDC 585 to discharge air filter media by isopropanol vapor according to ISO 16890-4
TDD 590
Thermodenuder TDD 590 for removal of volatile organic components (VOC) from aerosols
UDS 751
Ultrasonic Desintegrator UDS 751 for dispersing solutions, emulsions and suspensions by focused ultrasonic
VDS 562
Variable Dilution System VDS 562 for variable adjustable, pressure drop compensated dilution of aerols at defined air flow rates