DIL 557 Dilution System

DIL 550 Dilution System for static dilution (customised) of aerosols at static air flow rate (customised)

The DIL 557 Dilution System serves for the defined and reproducible reduction of particle concentrations in aerosols.
Dilution System for Aerosols DIL 557, frontal view
Dilution System for Aerosols DIL 557, frontal view
The main application of the DIL 5507 dilution system is the verification of test aerosols for testing clean rooms. DIN EN ISO 14644-3 defines the necessity of appropriate dilution systems when using test aerosols for verification. In the applied principle that corresponds to the standard VDI 3491-15, particles are removed from the sample aerosol according to the specified dilution ratio. The particle size distribution remains unchanged.

Standards

ISO 14644-3
VDI 2083
VDI 3491-6
VDI 3491-15
Interested?We will gladly advise you

+49 (351) 2166 430

contact form

Benefits

  • constant and reproducible aerosol dilution even under changing operation conditions
  • internal monitoring of the dilution ratio and visualisation
  • suitable for mobile operation (compressed air supply is not required)
  • long-term lifetime, minimum maintainance required
  • precice operation for both overpressure and underpressure
  • flow rate and dilution factor adjustable for customer requirements

Applications

From the aerosol flow to be diluted, a sample is passed through a thin capillary. The particle concentration of the capillary flow rate remains unchanged, whereas a HEPA filter removes nearly all particles from the bypassing flow rate. After the capillary and filter both flows are remixed. The dilution ratio results from the ratio between the two single flow rates.

Parameter titleUnitValue
purpose of conditioning - dilution of aerosols
sample condition, outlet - diluted aerosol
dilution factor - customised
aerosol, volumetric flow rate L/min customised
setting method - manual
sample condition, inlet - undiluted aerosol
power supply - 12 V DC; 30 mA
hose connector mm Ø 8 (optional Ø 10)
pressure drop kPa 0,8 ... 1,3
environmental condition, temperature °C 10 ... 50
environmental condition, max. counterpressure kPa ± 35
dimensions (w × h × d) mm 110 × 160 × 300
weight kg 1,5

Silimar products

DIL 550

Dilution System DIL 550 for static dilution (1:100) of aerosols at static air flow rate (28,3 L/min)

Dilution System for Aerosols DIL 550, frontal view
detail view

DIL 551

Dilution System DIL 551 for static dilution (1:10) of aerosols at static air flow rate (28,3 L/min)

DIL 550 Dilution System for Aerosols, type 551, view from right side
detail view

DIL 552

Dilution System DIL 552 for static dilution (customised) of aerosols at static air flow rate (28,3 L/min)

Dilution System for Aerosols DIL 552, frontal view
detail view

DIL 553

DIL 553 Dilution System for static dilution (1:100 or 1:10) of aerosols at static air flow rate (56,6 or 50 L/min)

Dilution System for Aerosols DIL 553, frontal view
detail view

DIL 555

DIL 555 Dilution System for static dilution (1:100) of aerosols at static air flow rate (2,83 L/min)

Dilution System for Aerosols DIL 555, frontal view
detail view

DIL 556

DIL 556 Dilution System for static dilution (1:10) of aerosols at static air flow rate (2,83 L/min)

Dilution System for Aerosols DIL 556, frontal view
detail view