Topas technologies test under real conditions and on the basis of current standards
The demands on indoor air quality have risen dramatically, due to an increasing awareness of fine dust and aerosols in general, and not least due to the worldwide pandemic situation from 2020 to 2022. Since people spend a large part of their lives indoors, particularly good indoor air has become a sign of quality for the manufacturers of building air conditioning systems. This has long been evident in completely new building ventilation concepts, for example in low-energy houses or hotels. Another important field of application for industrial filters is the protection of high-quality machines and components. Here, too, the demands on supply air quality are constantly increasing. With our versatile test systems, you are able to test general air filters, highly efficient HEPA and ULPA filters, and also gas turbine filters in various test routines according to current standards.
AFC 136
AFC 136 Test System for production control of filter elements (e.g. exhaust filter, HEPA filter)
GTS 114
Test System GTS 114 for testing air intake filter systems for rotary machinery (ISO 29461)
AFC 132 QC HEPA
AFC 132 QC HEPA Test System for quality control during production of small HEPA filter elements
AFS 150
AFS 150 Test System for automated scan testing of HEPA and ULPA filters according to ISO 29463-4 (EN 1822-4) and ISO 29463-5 (EN 1822-5)
AFS 152
AFS 152 Test System for manual scan testing of HEPA and ULPA filters according to ISO 29463-4 (EN 1822-4) and ISO 29463-5 (EN 1822-5)
AFS 155
AFS 155 Test System for oil thread leak test of HEPA filter according to ISO 29463-4 (EN 1822-4)
ALF 114
ALF 114 filter test system for general air filters according to ISO 16890, EN 779, ASHRAE 52.2
ATM 210
Atomizer Aerosol Generator ATM 210 for aerosol generation from liquids against counter pressure up to 10 bar, compressed air operated, moderate mass flow rate
ATM 210/H
Atomizer Aerosol Generator ATM 210/H for aerosol generation from liquids against counter pressure up to 10 bar, compressed air operated, high mass flow rate
ATM 211
Atomizer Aerosol Generator ATM 211 for aerosol generation from liquids against counter pressure up to 10 bar, compressed air operated, corrosion-resistant
ATM 230
Atomizer Aerosol Generator ATM 230 for aerosol generation from liquids, compressed air operated, high mass flow rate
ATM 231
Atomizer Aerosol Generator ATM 231 for aerosol generation from liquids, compressed air operated, submerged nozzle, high mass flow rates
ATM 240/L
Atomizer Aerosol Generator ATM 240/L for aerosol generation from liquids, compressed air operated, high mass flow rate, ideal for PSL aerosols acc. ISO 29463
DEHS
Liquid aerosol substance DEHS for operation with aerosol generators of the series ATM
DIL 540/C
DIL 540/C Dilution System for controlled static dilution (1:100) of aerosols at static air flow rate (28,3 L/min), digital status communication
DIL 541/C
DIL 541/C Dilution System for controlled static dilution (1:10) of aerosols at static air flow rate (28,3 L/min), digital status communication
DIL 545/C
DIL 545/C Dilution System for controlled static dilution (1:100) of aerosols at static air flow rate (3 L/min), digital status communication
DIL 546/C
DIL 546/C Dilution System for controlled static dilution (1:10) of aerosols at static air flow rate (3 L/min), digital status communication
DIL 550
Dilution System DIL 550 for static dilution (1:100) of aerosols at static air flow rate (28,3 L/min)
DIL 551
Dilution System DIL 551 for static dilution (1:10) of aerosols at static air flow rate (28,3 L/min)
DIL 552
Dilution System DIL 552 for static dilution (customised) of aerosols at static air flow rate (28,3 L/min)
DIL 553
DIL 553 Dilution System for static dilution (1:100 or 1:10) of aerosols at static air flow rate (56,6 or 50 L/min)
DIL 557
DIL 550 Dilution System for static dilution (customised) of aerosols at static air flow rate (customised)
EAN 581
Electrostatic Aerosol Neutralizer EAN 581 for generation of positive and/or negative ions for neutralisation or unipolar charging of aerosols
LAP 340/L
Optical Particle Counter LAP 340/L for analysis of particle size distributions and particle concentrations in aerosols, best for filter testing (2,83 L/min)
PAFWin
PAFWin software for the configuration, control, data logging and data analyses for Topas Test Systems
PASWin
PASWin software for configuration, control, data logging and data analyses of particle counters and aerosol spectrometer
SAG 420
Solid Aerosol Generator SAG 420 for aerosol generation from powders, belt dosing, high mass flow rates, best for motor intake filter testing acc. ISO 5011
SAG 440
Solid Aerosol Generator SAG 440 for aerosol generation from powders, belt dosing, best for ASHRAE dust (for ASHRAE 52.2, ISO 16890-3, EN 779)
TDC 584
Conditioning cabinet TDC 584 to discharge air filter and air filter media by isopropanol vapor according to ISO 16890-4
TDC 585
Conditioning chamber TDC 585 to discharge air filter media by isopropanol vapor according to ISO 16890-4