PAF 113 Test System
PAF 113 Test System for both particle separation and gas absorption/desorption of of air filters for passenger compartments (DIN 71460-1/2, ISO 11155-1/2)
The PAF 113 test system combined the advantages of PAF 111 particle test system and PAF 112 gas testing system. It povides a maximum of paramater testing for cabin air filters.
Standards
DIN 71460-1
DIN 71460-2
ISO 11155-1
ISO 11155-2
ISO 10121-1
ISO 10121-2
download
product sheet PAF 113Benefits
- standard compliant testing of filter media and filter elements
- combined testing with particles and with gases
- very flexible system configuration possible
Parameter title | Unit | Value |
---|---|---|
test flow rate | m³/h | 70 ... 700 |
test aerosol | - | DEHS, DOP, PAO, KCl, NaCl, ... |
test gases | - | n-Butane 80 ppm, toluene 80 ppm, sulfur dioxide 30 ppm, hydrogen sulfide 10 ppm |
measuring range, differential pressure | Pa | 0 ... 1000 (± 2 %) |
dimension of test specimen | mm | max. 600 × 300 |
operating medium, gas/air | - | room air at standard test conditions (23°C ± 2 K; 50 % ± 2 % RH) |
power supply | - | 400 VAC / 3P / 75 A / 50 ... 60 Hz and 3 × 230 VAC / 2 P / 16 A / 60 Hz |
aerosol generation technology | - | dust disperser SAG 410/L, Atomizer ATM 220, ... |
aerosol conditioning technology | - | Electrostatic Aerosol Neutraliser EAN 581 |
aerosol measurement instruments | - | aerosol spectrometer LAP 322 |
gas analysers | - | FID, NDIR |
sensors, others | - | temperature, relative humidity, absolut pressure |
dimensions (w × h × d) | mm | 3700 × 3000 × 3700 |